3000 Series Owner's Manual Computer Model: Inspiron 15–35 Regulatory Model: P40F Regulatory Type: P40F001/P40F002. Notes, Cautions, and Warnings. Step 1: Set the total oil quantity in ODME. Marpol has put a limit on how much total oil we can discharge in the wash water. This limit is 1/30000 of the total cargo carried. So in our example of product tanker, lets calculate. Total Cargo carried in the tanks to be cleaned: 30000 m3 @ 15 C. Total oil from the washing that can be discharged.

TEST No1 - 30L/NM Alarm Verification
1. Inform the Bridge OOW and Master. Call ECR to Open Air and Water on Deck.
2. Open Fresh Water Supply Valve (1), Fresh Water Valve (2) to Residual Tank and Air Supply Valve (3) in the (Pump Room)
3. Run one Hydraulic Valve pump (In CCR)
4. Check ODME Printer Paper
5. Switch ( ON ) the ODME system
Odme s-3000 manual pdf6. Press 'INPUT'
7. Press '3' (For PPM Set Up)
8. Press 'MAN' ( And then if asking for GPS position press 'AUTO')
9. Input ' 290 '
10. Press ' INPUT '
11. Press ' 4 ' (For Manual Speed in Knots)
Odme s-3000 manual pdf12. Press ' MAN '
13. Input ' 10 '
Manual14. Press ' INPUT '
15. Press ' 5 ' ( For Manual Flow Rate in m3)
16. Press ' MAN '
17. Input ' 1000 '
18. Press ' INPUT '
19. Press ' SAVE '
20. Switch to ( MONITOR) (On Top of ODME System) (And wait until the overboard valve will open and valve to slop will shut.
21. Press ' INPUT '
22. Press ' 3 '
23. Input ' 310 '
24. Press ' INPUT '
25. Press ' SAVE ' ( Alarm will sound)
26. Press (ALARM) reset button (Color Red) ( Overboard valve will shut and Slop valve will open.

Odme S-3000 Manual Pdf


27. End of test (Switch to 'STANDBY') (On Top of ODME System) And Reset to Normal Parameters - Auto Mode
28. Press ' INPUT '
29. Input ' 3 '
30. Press ' AUTO '
31. Press ' INPUT '
32. Press ' 4 '
33. Press ' AUTO '
34. Press ' INPUT '
35. Press ' 5 '

Odme Seil Seres S-3000 Manual


36. Press ' AUTO '
37. Press ' INPUT '

Odme S-3000 Manual Pdf


38. Press ' SAVE '
49. Switch ( OFF ) the ODME system (alarm will sound)
40. Press the (ALARM) button (Color Red). ( Alarm will disappear in few seconds )
41. Close Fresh Water Supply Valve (1), Fresh Water Valve (2) to Residual Tank and Air Supply Valve (3) in the pump room.
42. Inform ECR and Bridge OOW
This is only for reference and does not replace any procedures onboard. It is recommended to refer to your company procedures and equipment manual for your actual equipment onboard.

Odme S-3000 Ver.2 Manual

By: Elums

SS-2000 Oil Discharge Monitoring Equipment

We are offering a range of fully refurbished – with 24 months Darlas - Hellas Warranty on exchange basis SEIL SERES OIL DISCHARGE MONITORING EQUIPMENT Type ODME SS-2000.

This equipment is in full compliance with IMO RES A 586(XIV) – MEPC 51 (32) for Tanker Ships.

S-3000

The Seil Seres SS-2000 is suitable to be retrofitted to all Tanker Ships build before the year 2005.

ODME SS-2000 is required by MARPOL regulations and it’s a system for controlling the discharge into the sea of the oily products in ballast from the cargo spaces of tankers. The System is approved in accordance with Resolution A 586 (XIV) and MEPC 51 (32) for Oily Products.

The SS-2000 Seil Seres ODME system consists of the following major parts - units:

Odme S-3000 Operation Manual


  • CONTROLLER,
  • OIL CONTENT METER,
  • PPM MEASURER,
  • HYDRAULIC PANEL,
  • SAMPLING PROBE,
  • DP TRANSMITTER as part of the flow meter,
  • PITOT TUBE as part of the flow meter,
  • PRESSURE SWITCH,
  • MOTOR STARTER,
  • BULKHEAD PENETRATION MOTOR-SAMPLING
  • PUMP.

The Seil Seres ODME System supports features and options like:


  • Self-calibration,
  • Automatic zeroing,
  • Self-Cleaning of Measuring Vessel,
  • Across running,
  • Back flushing,
  • PPM Alarm,
  • Total Oil Limit Alarm,
  • Automatic Selection of Sample Monitoring
  • up to 3 channels etc.

The heart of the system is the Oil Content Meter, which uses an intrinsically safe multi cell detection system with fibres optics and automatic compensation, for detecting the actual PPM value of oil content.

Those are functions that have built inside the unit so the cost of maintenance will be kept as low as possible while the operation will be easily understood by the operator.

A very important feature for the Seil Seres ODME SS-2000 is the compatibility of its Major-Individual Units which can enable the service engineer to offer to the ship owner to upgrade his non-functioning or obsolete or old ODME system with a refurbished Seil Seres System offered by DARLAS – HELLAS with a full 24-months Warranty on Exchange Basis. This Retrofit Upgrade can be done easily and at low cost even when the ship is in operation and most of the times without HOT WORK.

We at DARLAS - HELLAS with service attendances in more than 450 ships and with more than 25 Retrofit Installationsand upgradesper year have a wealth of experience, which can assure you that you choose the right people to work with.

We Currently offer three ODME models for our retrofit installations. For Tanker Ships built before 2005 we offer either the Seres S.663 MK-III Model 911 ODME or the Seil Seres SS-2000. While for ships built after 2005 we offer the Seil Seres ODME model S-3000. These systems can be offered either as Completely Refurbished or as Brand new Systems with full 24-months warranty on exchangebasis.

Please contact us for further details.